Mini Solid-Core CT, 100A:26.6mA, 7mm (0.27") Hole Diameter, BCT-007-100UL

$ 470.00

description
Solid-core CT (Non-Openable), 100A:26.6mA, 7mm Hole Diameter, BCT-007-100
View More

More information

CT Type: Solid-Core

Max. Amperage: 100 amps

Inside Diameter: 7mm or 0.27 inches

Outside Diameter: 24 mm or 0.95 inches

Thickness: 12mm or 0.47 inches

Model: BCT-007-100UL

Certifications: CE, approved by UL for use with our UL Listed Omnimeters

Wire Gauge: For use on wire that is 10 AWG or smaller.

It is best to measure your wire diameter in millimeters, rather than use the AWG gauge. This is because the insulation thickness varies materially from one wire manufacturer to the next. It is much better to oversize your CT than to undersize it.

Our 7mm Solid Core CT is both economical and very popular with our customers. It is very compact and can measure the current of the majority of residential systems. These CTs are designed to be used in conjunction with our Omnimeter line of kWh meters.

These CTs are extremely accurate down to a few watts. They have 3759 internal turns, creating a 26.6 mA output at full amperage. They are also exceedingly precise at 0.1% accurate. Use these CTs for any system from under 1/4 amp to 100 amps.

  • Use 1 CT for 120 volt single phase North American, or 230 volt 2-wire foreign systems
  • Use 2 CTs for 120/240 volt single phase systems
  • Use 2 CTs for 3-phase 3-wire systems (no neutral)
  • Use 3 CTs for 3-phase 4-wire systems

Each CT comes with 72 inch wire leads.

These CTs have received UL Approval for use in combination with our UL listed Omnimeters for a complete UL Listed installation.

Each CT has a unique serial number, is individually tested, and indicates the correct orientation of the CT in relation to the load of the electrical system being metered.

These CTs have a very small internal diameter so if you're considering them, be sure that your wire diameter is less that 7mm.

For more information about our products and services, we encourage you to visit our online Knowledge Base, which provides spec sheets, videos, tutorials, FAQs, diagrams, and more.

Spec Sheet: Solid Core, 7mm, 100A CT

  • 5 stars: 2 (100%)
  • 4 stars: 0 (0%)
  • 3 stars: 0 (0%)
  • 2 stars: 0 (0%)
  • 1 star: 0 (0%)
F
Frank
Does not come apart or fall off

The mini current transformer easily fits in a crowed load center. The extra step of disconnecting a wire to run it through a solid core transformer eliminated worry that it might fall off.

This review is not motivated by unwanted rewards.

M
Muthukumar Mudaliar
Nice little CTs that fits within a 2-Gang Box for monitoring couple of Circuits

I have used these little CTs for monitoring my home RACK systems. Very accurate measurements were useful to identify high current devices and selectively turn them on/off as needed.

h
hans paulokat

is there a length limit for the leads between the CT and the connected meter?

EKM Metering Inc.

Our CTs come with 6 foot leads. CTs with extended wire length lose about 1% accuracy every 50’ of extension. We cannot certify accuracy when you extend the length of the CT wires. It is ideal to locate the meter and CTs at the power system you are monitoring and then you can go long distance with the RS485 communications – USB converter, EKM Push, etc., if applicable. Of course if the 1% difference is not an issue for your situation then extending the CT wires may work fine for you.

If you must extend your CT wires, I would recommend at the very least, that you solder the wire leads together to get the most solid connection possible.

I would not extend the length of the CT wires if accuracy is a main concern (revenue grade accuracy or billing). If you are using your meter as a monitoring tool only it should be fine.

A
Admin

Can I use this CT with 6 gauge stranded wire? I have a very tight space where these will be installed.

EKM Metering Inc.

No, I don't think #6 wire will fit in this CT model. #6 wire is usually 8mm in diameter or more. I would recommend using the BCT-013-200 (https://www.ekmmetering.com/products/solid-core-200a-13mm-ct) instead. It has a 13mm inside diameter, 36mm outside diameter. So it's also pretty small. The spec sheet (https://documents.ekmmetering.com/EKM-BCT-013-200-CT-spec-sheet.pdf) for that CT model shows it's overall dimensions.

A
Admin

What size wire and type insulation are the leads from the CT?

EKM Metering Inc.

This CT model has 24 AWG wires with extruded PVC insulation. Our larger CTs have 22 AWG wires, also with extruded PVC insulation.